1.      The platform (and ramps) must be stable and may be used on gently sloping gradients. Any rocking can be stopped by inserting a 30cm^2 metal plate. Ensure that the underside of the platform and between the black rubber feet and loadbar is kept clear of dirt and stones as this will cause fluctuating/scrolling weights; please note Intermediate Pit Users.

 

2.      During use, join the black screw caps on the blue cables with the black screw caps on the indicator (User Guide page 1.). After use, replace all black screw caps on the blue cables and indicator when detaching the indicator. This good management will stop any damp/water/dust lodging inside the cables/indicator. If this happens it can be dried out by using a hairdryer for 5-10 minutes. (damp will cause fluctuating/scrolling weights.)

 

3.      BEFORE FIRST USE, CHARGE UP OVERNIGHT. Do NOT recharge until the indicator shows "batt" and 5-10 minutes later switches itself off. Charging the flat battery will take 6 hours, between 10–35 degrees C. extending to 12 hours at high or low temps. The battery is protected from overcharging. This good management will therefore give an internal battery run time of 8 hours or approximately 500 animal weighings, WHEN IN CONTINUOUS USE.

 

4.      For the UK, the mains adapter for charging must be on the 12v setting. (for pre. 01-08-06 orders) NOTE: Charging adaptor connections – RED TO RED, BLACK TO BLACK. (BLACK TO BLUE for pre. 01-08-06 orders). "charging E-F" must be scrolling for the indicator to charge; if not or "L.Volt" appears, check the 12v setting or for loose connections. Overseas countries may require a different volt setting for "charging E-F" to appear. (for pre. 01-08-06 orders).

 

5.      If "batt" appears whilst in use, a mains booster charge for 20-30 mins will give enough power for approx. 30 mins use. Accuracy will be maintained. This must NOT be done on a regular basis as the battery will develop a memory. Please note: the platform indicator can be used while charging.

 

6.      For all weighing platforms with filled in sides or guide rails (i.e. Supreme Plus Extra, Supreme Plus, Supreme etc), if the filled in sides/guide rails become loose, the user must tighten the top 20mm nut first from left to right, on each corner, and then tighten the bottom nut, also from left to right.

 

7.      Please regularly read the EziWeigh User Guide for other operating rules

For any other queries contact Horse Weigh

Tel       +44 (0)7774 783247 or +44 (0)1547 520169 william@horseweigh.com

 